Home / Products / Classification per Function / Formaldehyde remotionem Aeris Filter

Formaldehyde remotionem Aeris Filter

Nantong Henka Environment Solutions Co.,Ltd.


Nantong Henka Environment Solutions Co.,Ltd. was founded in 2004. Henka is one of the famous and professional air filter manufacturers for air purifiers, air cleaners, and ventilation systems. Our air filters include HEPA, VOC removal filters, Formaldehyde removal filters, Activated Carbon filters, Odor removal filters, HVAC filters, i-Hepa ventilation purification devices, and IFD purification devices.
Henka amet elit colum aer pro notis clarorum mundantium aeris et mundatorum in foro Americano Septentrionali et in foro Sinarum. Henka non solum columellas aeris, sed etiam solutiones purificationis professionales praebet.
Henka in Haimen urbe, provincia Jiangsu sita est, quod solum 120 chiliometrorum ab Shanghai.Henka habet ISO14001:2015, ISO9001:2015 et ISO45001:2018 certificationes, efficientia et resistentia aeris systematis colum instrumentorum, strepitus test lab, 30 cubicorum metra examinis locus pro formaldehyde et VOC efficientiam removendi, CADR locus probandi aeris purgatorius. ASHRAE 52.2 Filtra aeris in probatione adhibetur.
Cum plus quam XX annos experientiae operandi cum US machinator team, possumus designare productum secundum speciem, delineationes, exempla, vel etiam ideas a clientibus nostris et solutiones filtrationis professionalis aeris nostris clientibus praebent.
  • 0

    Constitutio

  • 0

    Factory Area

  • 0+

    Numerus Employees

  • 0+

    Industria Usus

News
Nuntius videre
Industria scientia
Quomodo cogitas spatium amplitudinis vel spatium coverage ad faciendum formaldehyde-remotionem aeris colum efficacissimae?

Ut a formaldehyde filter aer, removere ut plurimum valeat, locus amplitudo vel area coverage consideranda est. Hic sunt nonnullae suggestiones et factores ut adiuvent idoneam camerae magnitudinem vel aream coverage determinare:

1. Filter CADR valor: Mundus aer traditio rate (CADR) index colum colum effectus aeris est. Quo altius cadr valor, eo melior facultas aeris tractandi colum. Filtrum elige cum congruenti CADR valore ad usus necessarios cubiculi magnitudine.

2. Voluminis conclave: Altitudo, longitudo, et latitudo conclavis continget debitam aream colum colum coverage. In universum, ampliores conclavia potentiores columellas aeris postulant ut formaldehyde remotionis efficax.

Formaldehyde concentratio: Prima intentio formaldehyde in cella etiam afficit requiritur coverage area. Si formaldehyde concentratione altiores sunt, filtrum cum area maius coverage ad efficacem remotionem requiri potest.

4. VENTILATIO: Ventilatio cubiculi etiam afficit coverage area colum. Si locus bene ventilatus est, concentratione formaldehyde inferior potest esse, reducendo requisitam aream coverage.

5. Numerus eliquarum: In amplioribus spatiis vel pluribus conclavibus, multae columellae aereae institui possunt ad curandum formaldehyde efficaciter ab omni area removendum.

6. Filter collocatio: Locatio aëris colum colum etiam afficit suam aream coverage. Colum ponens in centro cubiculi vel prope fontem formaldehyde emissio, augere potest eius efficaciam in tollendo formaldehyde.

7. Conclave propositum: Finis cubiculi potest etiam afficit aream debitam coverage. Exempli gratia, cubicula vel cubicula nuper renovata cum multa supellectile maiorem coverage aream requirere possunt, sicut haec cubicula plura formaldehyde dimittere possunt.

8. Commendationes Manufacturer: Commendationes aerem sequere fabricantis filter ut exemplar colum congruum et spatium coverage pro specificae magnitudinis tuae definias.




Quomodo evacuatio condicionis cubiculi afficit coverage area formaldehyde-movendi aerem colum?

Conditiones cubiculi evacuationis notabilem habent ictum in coverage area ipsius formaldehyde filter aer, removere . Hic paucae rationes sunt quomodo VENTILATIO colum coverage afficit:

1. Bene ventilata: Si locus bene ventilatus, formaldehyde et alii pollutantes naturaliter extra per fenestras, ostia, vel alia spiramenta evadere possunt. In hoc casu, aer filter insights area relative parva potest esse quia concentrationes tectis formaldehyde inferiores sunt.

2. Pauper VENTILATIO: In conclavibus male ventilatis, formaldehyde et aliis inquinamentis intra tecta cumulare potest, causando concentraciones formaldehyde oriri. In hoc casu, colum aer cum majori coverage spatio requiri potest ad remotionem efficacem formaldehyde.

3. Aeris circulatio: Bonus aer circulatio adiuvat meliorem efficientiam aeris sparguntur. Si pauper circulatio aeris in conclavi est, formaldehyde in aliquibus locis cumulare potest, causando concentrationes locales formaldehyde oriendi. In hoc casu, necesse est ut in diversis locis in diversis locis eliquationes aeris multiplices instituantur, ut pleniorem coverage consequantur.

4. Velitaria aeris qualitas: Outdoor aeris qualitas potest etiam afficere elucidationem conclavis. Si vis aeris qualitas pauperis est, nimis VENTILATIO ut velit scelerisque facere domum ingredi, afficiens area coverage aeris sparguntur.

5. Temporis mutationes: temporis mutationes afficere VENTILATIO cubiculi. Exempli gratia, in hieme, propter temperaturas velit demittere, populus evacuatione reducere potest, causando concentratione tectis formaldehyde augendis. In hoc casu, colum aer cum majori coverage spatio necessarius est ad resistendum provocationibus temporum mutationum.

VI. Aedificium structuram: Constructio et ratio aedificii etiam afficiunt evacuatione cubiculi. Exempli gratia, aliqua aedificia pauperes ventilatione naturalia habere possunt, quae filtra aeris cum maioribus coverage in locis emendare possunt.